Calibration method of Zhongke mixer belt scale: adjust the "automatic / manual" switch on the speed controller to the manual position, adjust the speed to the small potentiometer, and turn on the power supply of the host and speed controller. After 15 minutes, start the belt scale, adjust the speed on the speed controller, let the potentiometer run the belt (400-500 RPM), and test the zero point as required. Press F3 to move the cursor to the K value to be calibrated, and press F5 to place some sandbags on the running belt with known weight (cumulative weight > 100KG).
此時(shí),以流的形式顯示重量或沙袋的累積值,然后將重量或沙袋的重量發(fā)送給K值。道路的K值由微機(jī)決定。計(jì)算新的K值,以同樣的方式校準(zhǔn)2-3次,直到累積流量等于實(shí)際流量。其他道路標(biāo)記方法與上述方法相同。
At this point, the weight or the accumulated value of the sandbag is displayed as a stream, and then the weight or the weight of the sandbag is sent to the K value. The K value of the road is determined by the computer. Calculate the new K value and calibrate 2-3 times in the same way until the cumulative flow equals the actual flow. Other road marking methods are the same as above.
螺旋電子秤的校準(zhǔn)方式有兩種:將速度控制器上的“自動(dòng)/手動(dòng)”開(kāi)關(guān)置于手動(dòng)位置,將給定電位計(jì)的速度調(diào)節(jié)到較小的速度,啟動(dòng)螺旋電子秤。先將水泥內(nèi)部清洗干凈,然后按零位測(cè)量法進(jìn)行零位測(cè)量。按F3將光標(biāo)移動(dòng)到第7個(gè)K值的前面,按F5調(diào)整給料機(jī)控制的速度,使電位器旋鈕可以取下。同時(shí)擰緊螺絲和電子秤,使其在出口處排出。水是穩(wěn)定的。攪拌站攪拌帶完成后,按回車鍵,將物料的實(shí)際重量發(fā)送到K值。按Enter確認(rèn)。這是K值自動(dòng)生成一個(gè)新的K值的地方,以同樣的方式校準(zhǔn)。完成校正工作,直累積重量等于實(shí)際重量為止。
There are two ways to calibrate the screw scale: set the "auto / manual" switch on the speed controller to the manual position, adjust the speed of the given potentiometer to a smaller speed, and start the screw scale. First, clean the inside of the cement, and then measure the zero position according to the zero position measurement method. Press F3 to move the cursor to the front of the 7th K value, and press F5 to adjust the speed of feeder control so that the potentiometer knob can be removed. At the same time, tighten the screws and the scale to make it discharge at the outlet. Water is stable. After the mixing belt of the mixing station is completed, press enter to send the actual weight of the material to K value. Press enter to confirm. This is where the K value automatically generates a new K value, calibrated in the same way. Complete the calibration until the accumulated weight is equal to the actual weight.
混凝土攪拌機(jī)水的標(biāo)定方法:水的標(biāo)定方法簡(jiǎn)單,因?yàn)橄到y(tǒng)采用水表,即高精度電子計(jì)量水表。將每公斤水表對(duì)應(yīng)的脈沖量發(fā)送到第九路的K值是很重要的。是的,例如,我們的工廠使用Φ40套水等于每公斤22脈沖。因此,將第9個(gè)k值改為22,完成校準(zhǔn)。第九個(gè)“時(shí)間”是水的百分比,零點(diǎn)是水的跟蹤系數(shù)。延遲就是加水的延遲。在使用道路時(shí),六路不能連接皮帶秤。水路的自動(dòng)DA值由道路輸出。
Concrete mixer water calibration method: water calibration method is simple, because the system uses water meter, that is, high-precision professional electronic metering water meter. It is important to send the pulse corresponding to the water meter per kilogram to the K value of the Ninth Circuit. Yes, for example, our factory uses Φ 40 sets of water equal to 22 pulses per kilogram. Therefore, change the 9th K value to 22 to complete the calibration. The Ninth "time" is the percentage of water, and the zero point is the tracking coefficient of water. Delay is the delay of adding water. When using the road, six ways cannot be connected to the belt scale. The automatic Da value of the waterway is output by the road.